GFC CONTROL CIRCUIT 

To move the loco, field of Traction Alternator is to be excited by exciter generator. This work is done with the help of GFC contactor. It is electro magnetic contactor. To pickup this contactor GFC coil circuit is designed. This circuit starts from wire no. 13. When both control stand GFCO kept in close and MH closed (MH 1 – 8), the supply of wire no. 13 goes to wire no. 6 via wire no. 30E, 30C, and 30CC. Supply of wire no. 6 goes to GFC coil through following normally close interlocks

BKT (M)                 NCI                               6-6A 
ECS(R)                   NCI                               6A-6B 
GFOLR                  NCI                                6B-6C 
GR1                       NCI                                6C-6D 
BKT (M)               NCI                                6D-6E 
TR                         NCI                                6E-6F 
CK3                      NCI                                6F-6H 

GF coil will energize by wire 6H positive and wire 4 negative and GFC contactor pick up. 

Other than this following interlocks are provided parallel to BKT (M) & TR (NCI). 

NOI of P32 (6D-6F), NOI of P2 (6D-6F) will close at the time of parallel transition. 

MCO NOI (6D-6F) will close at the time of TM isolation.





.

Disclaimer: The Information/News/Video provided in this Platform has been collected from different sources. We Believe that “Knowledge Is Power” and our aim is to create general awareness among people and make them powerful through easily accessible Information. NOTE: We do not take any responsibility of authenticity of Information/News/Videos.